Forced Air Furnaces

American Standard
Many efficient heating and cooling options for homeowners to choose from.
Freedom® 80 Single-Stage Furnace
 
Multispeed blower
Operates quietly and efficiently, gently warming
and maintaining comfort.
 
Adaptive silicone carbide hot
surface igniter
Prevents overheating, which results in a highly reliable
 ignition system and the longest possible service life.
 
Heavy steel insulated cabinet
Holds more heat in the furnace. It also ensures greater durability and quieter operation.
 
Multi-port in-shot burners
Perfectly shape the flame cone to maximize heating while reducing fuel usage. No service adjustments 
necessary.
 
Aluminized steel heat exchanger       
Crimped, not welded, to prevent cracks from heatstress, 
its stamped serpentine channel offers the greatest 
efficiency in less space. Backed by our 20-year,
non-prorated, limited warranty.
 
Induced draft venting
Quietly draws hot gases through the heat exchanger, maximizing the heat transfer efficiencies of the exchanger design. 
 
 
 
 
Freedom® 90 Two-Stage High Efficiency 
Single-Stage Furnace
 
Variable speed blower motor
Operates at a lower, more efficient speed than 
conventional blowers. With American Standard's 
exclusive Comfort-R feature, there is a greater humidity control during cooling. (Freedom 90 Comfort-R Variable Speed)
 
Multispeed blower motor
Operates quietly and efficiently, gently warming and maintaining comfort. Handles all central air conditioning needs, too. (Freedom 90 Two-Stage
and Single-Stage)
 
Two-stage gas valve
Works efficiently with the multispeed motor, providing only as much fuel as each stage requires. (Freedom 90
Comfort-R Variable Speed and Two-Stage)
 
Induced draft venting
Quietly draws hot gases through the heat exchanger, maximizing the heat transfer efficiencies of the exchanger design.
 
Multi-port in-shot burners
Perfectly shape the flame cone for the maximum heat possible while using less fuel.
 
Adaptive hot surface silicone nitride 
igniter
Starts burners electrically for safe, efficient operation. 
There's no pilot light constantly burning fuel.
 
Aluminized steel heat exchanger
Crimped, not welded, to prevent cracks from heat stress. Stamped serpentine channel offers the greatest efficiency in less space. Backed by our lifetime limited warranty.
 
Stainless steel secondary heat exchanger
Captures more of the heat you pay for.
 
Heavy steel insulated cabinet
Holds more heat in the furnace to better warm your home. Also assures greater durability and quieter operation.
 
Cleanable filters
Means you can rinse or vacuum it without buying 
replacements each time. (Freedom 90 Comfort-R 
Variable Speed, Two Stage and High Efficiency
Single-Stage.
 
 
 
Freedom® 95 Comfort-R™ VariableSpeed, Modulating Communicating Furnace
 
with user interface (Ultimate models)
AccuLinkTM communicating capability 
Enables system to "communicate" it's status and settings to the comfort control, while also allowing remote monitoring and programming by phone. * Clearly relays diagnostics to your installer or servicer for responsive maintenance. 
 
Three-wire connection 
(Ultimate models)
Simplified connection to the Comfort Control enables faster, easier installation that is less invasive to your home.
 
Variable-speed blower motor with 
Comfort-RTM
Operates at a lower, more efficient speed than 
conventional blower motors. With American Standard's 
exclusive Comfort-R feature, there is greater humidity 
control during cooling.
         
Induced draft venting
Variable-speed draft blower assembly quietly draws hot gases through the heat exchanger to maximize heating.
         
 Adaptive hot surface silicon nitride 
igniter
Starts burners electronically for safe, efficient 
operation - eliminating the need for a fuel-burning 
pilot light.
 
Three-stage modulating gas valve 
(Ultimate models)
Highly reliable, proven design that operates at 40%, 65% and 100% firing rates to provide for greater efficiency and better comfort control.
          
Two-stage gas valve 
(Premium models)
Results in greater efficiency by providing just the right amount of fuel for each stage.
 
Multi-port in-shot burners
Perfectly shape the flame cone to maximize heating while using less fuel.
 
Aluminized steel primary heat 
exchanger
Crimped, not welded, to prevent cracks from heat stress. Stamped serpentine channel offers the greatest efficiency in less space. Backed by our lifetime limited warranty.
 
Three-row secondary heat 
exchanger (Ultimate models)
Made of AL29-4C stainless steel to capture more of the heat you pay for.
 
Stainless steel secondary heat 
exchanger (Premium models)
Captures more of the heat you pay for. Also backed by our lifetime limited warranty.
 
 
 
 
>> 20-Year, non-prorated, limited
warranty on heat exchanger <<
 
>> 5-Year limited warranty on
all other parts <<

 

 

Self-diagnostic controls
Manage every function with digital accuracy. Include safety features and a built-in troubleshooting system.
 
Sound-insulated blower compartment
Assures the quietest possible operation.
 
100% fresh air option
Uses 100% outdoor air for combustion for increased equipment life and cleaner air.
 
Dual door latches
Allows easy access to the filter for cleaning or changing. (Freedom 90 Comfort-R Variable Speed, Two-Stage and High Efficiency Single Stage. On up flow models only.)
 
 
 
>> Lifetime Limited Warranty
on heat exchangers <<
 
>> 5-Year Limited Warranty
on all functional parts <<
 
>> Optional Extended 10-Year Warranty
on parts and labor <<
 
 
 
 
 
 
 
Self-diagnostic controls
Manage every function with digital accuracy. Includes safety features and a built-in troubleshooting system.
 
Sound-insulated blower
compartment
Ensures the quietest possible operation.
 
100% fresh air option
Uses 100% outdoor air for combustion to increase equiptment life.
 
Dual door latches
(Upflow models only)
Allows easy access to the filter for cleaning or changing.
 
Heavy steel insulated cabinet
Holds more heat in the furnace to better warm
your home. Also ensures greater durability and
quieter operation.
 
Cleanable filter
Means you can rinse or vacuum it without buying replacements each time.
 
>> Lifetime Limited Warranty
on heat exchangers <<
 
>> 5-Year Limited Warranty
on all functional parts <<
 
>> Optional Extended 10-Year Warranty
on parts and labor <<
 
* An American Standard 900 Series Comfort Control
is required for all Freedom 95 communicating furnaces.
Telephone Access Module (TAM) required for remote
system monitoring.